Chinese Journal of Diagnostics(Electronic Edition) ›› 2017, Vol. 05 ›› Issue (01): 1-7. doi: 10.3877/cma.j.issn.2095-655X.2017.01.001

Special Issue:

• Imaging Diagnostic Studies •     Next Articles

Clinical application of electrocardiogram-triggered high-pitch dual-source coronary CT angiography at 80 kV low radiation dose integrated iterative reconstruction technology

Yang Han1, Ruijuan Han2, Guoqiang Chen1, Ruiping Zhao2, Kai Sun1,()   

  1. 1. Department of Radiology, Baotou Central Hospital, Baotou 014040, China;Department of Medical Imaging Research Institute, Baotou Central Hospital, Baotou 014040, China
    2. Department of Radiology, Baotou Central Hospital, Baotou 014040, China; Department of Cardiology, Baotou Central Hospital, Baotou 014040, China
  • Received:2016-06-07 Online:2017-02-26 Published:2017-02-26
  • Contact: Kai Sun
  • About author:
    Corresponding author: Sun Kai, Email:

Abstract:

Objective

To assess the impact of image quality and radiation dose levels of low tube potential with electrocardiogram (ECG)-triggered high-pitch coronary computed tomography angiography (CCTA) of 2nd generation dual-source computed tomography.

Methods

One hundred and twenty patients with suspected coronary arteries underwent high-pitch prospectively ECG-triggering CCTA.All subjects had registered for this research and hospitalized.Prospective study was conducted with dual-source coronary computed tomography using iodine contrast agents.All patients signed informed consent of the Ethical Committee of Baotou Central Hospital and the ethics committees approved the consent procedure.Sixty patients were examined with high-pitch mode by a 2nd-generation dual-source CT system at 80 kV and SAFIRE iterative reconstruction (80 kV+ SAFIRE) or with 80 or 100 kV and FBP reconstruction (80 kV+ FBP, 100 kV+ FBP) respectively.Subjective image quality was evaluated double-blindly by two experienced radiologists.Objective image quality was measured by means of various regions of interest.

Results

The noise values of aortic root, right coronary artery(RCA), left coronary artery(LAM) in 80 kV+ SAFIRE group (23.62±5.57, 18.89±8.80, 17.42±5.94) were lower than those of 80 kV+ FBP group(31.66±8.41, 24.15±15.84, 22.45±5.62) as well as 100 kV+ FBP group(27.38±8.01, 22.76±4.41, 22.09±4.51), the differences were significant (F=19.09, 4.36, 22.15; P<0.05). The signal to noise ratios (SNR) of aortic root, RCA, LAM in 80 kV+ SAFIRE group (24.89±8.37, 32.33±12.80, 34.46±11.73) were higher than those of 80 kV+ FBP group (18.84±6.43, 24.89±9.08, 25.70±7.90) and 100 kV+ FBP group (19.66±4.43, 24.12±7.35, 24.93±7.86) , the differences were also significant (F=21.08, 16.69, 26.55; P<0.01). The effective dose (ED) of 80 kV+ SAFIRE , 80 kV+ FBP groups decreased significantly compared with 100 kV+ FBP group (F=38.14; P<0.01). The ED of three group were (0.47±0.03)mSv, (0.47±0.05)mSv, (1.00±0.04)mSv respectively.

Conclusions

High-pitch prospectively ECG-triggered CCTA at 80 kV enables to obtain diagnostic image quality with 2nd-generation CT using iterative reconstruction technique in patients.This methodology can reduce radiation dose levels obviously compared with the 100 kV group.The radiation dose of the 80 kV group is reduced by 53%.

Key words: Coronary vessels, Tomography, x-ray computed, Image processing, computer-assisted